The Gravity Analog Signal Isolation Module is vital for maintaining signal integrity in electronic systems, operating on a 5.0V supply with minimal analog error between two terminals, featuring a 4-second response time and PH2.0-3P connector type, designed for efficient integration into various projects. It includes two primary terminals: the non-isolation terminal (MCU Terminal) and the isolation terminal (SEN Terminal), each with specific supply voltages and analog input/output ranges, emphasizing the importance of connecting the SEN terminal to sensors or modules and the MCU terminal to the main control board. This module enables users to achieve reliable signal isolation, enhancing the overall performance of electronic systems.

Overhead shot of black analog isolator with labeled ports and visible screws-DFRobot product sku:DFR0504 image.
  • Docs
  • Tech Specs
  • Specification

    Parameter Value
    Operating Voltage 5.0V
    Response Time 4 seconds (Typ)
    Analog Error between Two Terminals <± 20mV (Typ)
    Connector Type PH2.0-3P
    No-load Current 75mA
    Dimension 42 x 32mm / 1.65 x 1.26 inch
    Non-isolation Terminal (MCU Terminal)
    Supply Voltage 5.0 ± 0.1V
    Analog Output 0 ~ 5.0V
    Isolation Terminal (SEN Terminal)
    Output Voltage 5.0 ± 0.2V
    Analog Input 0 ~ 5.0V

    Pinout

    Gravity: Analog Signal Isolation Module Pinout

    Num Label Description
    1 A Analog Signal Output(0~5.0V)
    2 + Power Input VCC(5.0±0.1V)
    3 - Power Input GND
    4 A Isolation Power Output GND
    5 - Isolation Power Output VCC(5.0±0.2V)
    6 A Analog Signal Input(0~5.0V)

    As shown in the figure below, this analog signal isolator has two connectors, one is on the left and another is on the right. The left connector named SEN should be connected to the sensor or module. The right connector named MCU should be connected to the main control board.

    Gravity: Analog Signal Isolation Module Connector Overview

    FAQ

    • Hi DFRobot, can I use this voltage isolator with the SEN0198 High Temperature probe? Since it has an analog output to for the resistance at a given temperature. And I am using the SEN0198 with other sensors with analog output also.

      You can just use one DFR0504 if you have one pH and one EC sensor, and this module doesn't need to code, just plug between one sensor and Arduino