There are two solder pads of data bits A0 and A1 on the back of the LED display (disconnect: 0/connect: 1). The four slave addresses can be realized by the combination of A0 and A1, shown as below.

The address format of LED controller:

MSB D6 D5 D4 D3 D2 D1 LSB
1 1 1 0 0 A1 A0 R/W

Note: D3~D7 should not be changed. When writing, D0 R/W=0, so the addresses are:

A1 A0 Address
0 0 0xE0
0 1 0xE2
1 0 0xE4
1 1 0xE6

IIC Communication

The data of microprocessor communicate with the LED driver control IC via two-line bus interface. During data input, DIN signal must keep unchanged when CLK is at high level. Only when CLK clock signal is at
low level can DIN signal be changed. The condition of starting data input is that DIN changes from high
to low when CLK is at high level, and its condition of ending is that DIN changes from low to high
when CLK is at high level, which is in accordance with IIC communication protocol.

The operation of writing LED display data shall follow the principle of “from low bit to high bit” of display address and “from low bit to high bit” of data byte.