Gravity: Analog EMG Sensor

SKU: SEN0240

Gravity: Analog EMG Sensor(by DFRobot and OYMotion) offers a noninvasive method to detect muscle and neural activities through sEMG, featuring integrated filtering and amplification circuits. Its output is analog, based on a 1.5V reference voltage, and ranges from 0 to 3.0V. The sensor is compatible with Arduino, allowing users to analyze muscle tension and strength. Easy to use with dry electrodes, it is ideal for both static and dynamic applications, offering a longer lifespan compared to traditional medical electrodes. The sensor is suitable for various human-computer interaction applications, expanding beyond traditional medical uses.

Overhead shot of analog EMG sensor modules showing components and connectors-DFRobot product sku:SEN0240 image.

Downloadable Resources

  • Docs
  • Tech Specs
  • Blog
  • Specification

    • Signal Conditioner Board
    Parameter Specification
    Supply Voltage 3.3V~5.5V
    Operating Voltage 3.0V
    Detection Range +/-1.5mV
    Electrode Connector PJ-342
    Module Connector PH2.0-3P
    Output Voltage 0~3.0V
    Operating Temperature 0~50℃
    Size 22mm*35mm (0.87inch*1.38inch)
    • Dry Electrode Board
    Parameter Specification
    Electrode Connector PJ-342
    Wire Length 50cm(19.69inch)
    Plate Size 22 * 35 mm(0.87inch*1.38inch )
    weight 36g

    Pinout

    Analog_EMG_Sensor_Pinout

    Num Label Description
    1 A Analog Signal Output(0~3.0V)
    2 + Power Supply Anode(3.3~5.5V)
    3 - Power Supply Cathode(0V)
    4 PJ-342 Probe Wiring Connector
    thumb
    A Christmas present for cute kid & girl - A Clever Rabbit Hat - an EMG sensor based

    This is an EMG sensor I bought from DFRobot. An EMG sensor can detect surface electromyography to reflect muscle and neural activities of human. Combining with a rabbit hat and several other stuff, it was evolved into a clever hat that can detect human facial expression such as scowling, grimacing, shocking, etc. Put the dry electrode to the area to be detected, the sensor will output analog signal to indicate the intensity of muscle activities. Let’s speak less and just get started!

    author
    DFRobot Dec 21, 2018
    thumb
    Head-mounted Myoelectric Mouse

    Discover how advanced technologies like motion sensing, myoelectric sensing, and speech recognition can transform accessibility. Enable hands-free mouse control, detect tooth muscle movements for mouse clicks, and utilize voice commands for fast control and input.

    author
    DFRobot Oct 30, 2017

    FAQ

    • The sensor reading is abnormally large or unchanged.

      1. Check whether the power supply of your sensor is stable;
      2. Please check whether the direction of the electrode patch is consistent with the direction of the muscle (as shown below), and the electrode patch should be tied to a large area of exposed skin.
      3. Try pulling out the connector of the sensor electrode to see if the reading is normal.
      You can also check out this quiz video:

      https://drive.google.com/file/d/1ANKqwHs0pEY-TzOjP-e0kYbKdSF-vMTM/view?usp=sharing

    • Where should I put the dry electrode? Is there any special requirement?
      In general, the corresponding 3 metal dry electrode plate needs not pay attention to the reference voltage. It only need to consistent with the direction of muscle.