Reference
Last revision 2025/12/29
Principle
An optical filter (long-wave pass ) that cuts off the visible and near infra-red radiant flux is integrated in the package to provide ambient and sunlight immunity. Its FOV is small as 5°, which means for a heat source with an outer diameter of 10cm, the maximum detection distance of the sensor can reach up to 116cm.
In addition, we use shielding wires to reduce external radiation interference to the sensor as well to decrease its own radiation interference to the outside environment, which makes the sensor able to apply to all kinds of complicated industrial situations. At the same time, the accuracy of the product has been increased a lot.
The relation between the output temperature T(℃) and the voltage U(V) the probe output: T=U/3*340-70(If the measured temperature is wrong please change 340 to 450)
- The field of view(FOV) of the sensor is 5°. The target dimension and the optical properties of the IR temperature sensor decided the maximum distance between the target and the probe. The field of view of the sensor is shown below.

- The gradient diagram of measuring accuracy of the sensor is shown below (To is the measured temperature; Ta is the temperature of the environment the sensor locates in). Please note that the temperature error only applies to a certain isothermal condition, and it’s only valid when the detected object is fully filling in the FOV of the sensor.