Example Code for Arduino-Get Data

Input the baseline value to the function `sensor.writeBaseLine();`If you don't want to set the baseline, please disable this function in the sample program. The sensor will automatically calibrate the baseline, but it would be a pretty long process. after the function uploaded to UNO, open the serial port monitor to check the carbide dioxide concentration and TVOC concentration.

Hardware Preparation

  • DFRduino UNO R3 (or similar) x 1
  • Gravity: CCS811 Air Quality Sensor x 1
  • Jumper wires

Software Preparation

Wiring Diagram

Connection Diagram.png

Other Preparation Work

Please run the sensor for 48hours when using it for the first time.

Sample Code

/*!
 * @file readData.ino
 * @brief Read the concentration of carbon dioxide and TVOC
 * @n Experiment phenomenon: read data every 0.5s, and print it out on serial port. 
 *
 * @copyright	Copyright (c) 2010 DFRobot Co.Ltd (http://www.dfrobot.com)
 * @licence     The MIT License (MIT)
 * @author [LuoYufeng]([email protected])
 * @version  V0.1
 * @date  2019-07-19
 * @get from https://www.dfrobot.com
 * @url https://github.com/DFRobot/DFRobot_CCS811
 */
#include "DFRobot_CCS811.h"

/*
 * IIC address default 0x5A, the address becomes 0x5B if the ADDR_SEL is soldered.
 */
//DFRobot_CCS811 CCS811(&Wire, /*IIC_ADDRESS=*/0x5A);
DFRobot_CCS811 CCS811;

void setup(void)
{
    Serial.begin(115200);
    /*Wait for the chip to be initialized completely, and then exit*/
    while(CCS811.begin() != 0){
        Serial.println("failed to init chip, please check if the chip connection is fine");
        delay(1000);
    }
}
void loop() {
    if(CCS811.checkDataReady() == true){
        Serial.print("CO2: ");
        Serial.print(CCS811.getCO2PPM());
        Serial.print("ppm, TVOC: ");
        Serial.print(CCS811.getTVOCPPB());
        Serial.println("ppb");
        
    } else {
        Serial.println("Data is not ready!");
    }
    /*!
     * @brief Set baseline
     * @param get from getBaseline.ino
     */
    CCS811.writeBaseLine(0x447B);
    //delay cannot be less than measurement cycle
    delay(1000);
}

Result

Result2

Was this article helpful?