Reference
Last revision 2026/01/21
Library
Download and install the ENS160 Library and examples.
Download and install the BME280 Library and examples.
(About how to install the library?)
API Description
/**
* @fn setPWRMode
* @brief Set power supply mode
* @param mode Configurable power mode:
* @n ENS160_SLEEP_MODE: DEEP SLEEP mode (low power standby)
* @n ENS160_IDLE_MODE: IDLE mode (low-power)
* @n ENS160_STANDARD_MODE: STANDARD Gas Sensing Modes
* @return None
*/
void setPWRMode(uint8_t mode);
/**
* @fn setTempAndHum
* @brief Users write ambient temperature and relative humidity into ENS160 for calibration compensation of the measured gas data.
* @param ambientTemp Compensate the current ambient temperature, float type, unit: C
* @param relativeHumidity Compensate the current ambient temperature, float type, unit: %rH
* @return None
*/
void setTempAndHum(float ambientTemp, float relativeHumidity);
/**
* @fn getENS160Status
* @brief This API is used to get the sensor operating status
* @return Operating status:
* @n eNormalOperation: Normal operation;
* @n eWarmUpPhase: Warm-Up phase;
* @n eInitialStartUpPhase: Initial Start-Up phase;
* @n eInvalidOutput: Invalid output
*/
uint8_t getENS160Status(void);
/**
* @fn getAQI
* @brief Get the air quality index calculated on the basis of UBA
* @return Return value range: 1-5 (Corresponding to five levels of Excellent, Good, Moderate, Poor and Unhealthy respectively)
*/
uint8_t getAQI(void);
/**
* @fn getTVOC
* @brief Get TVOC concentration
* @return Return value range: 0–65000, unit: ppb
*/
uint16_t getTVOC(void);
/**
* @fn getECO2
* @brief Get CO2 equivalent concentration calculated according to the detected data of VOCs and hydrogen (eCO2 – Equivalent CO2)
* @return Return value range: 400–65000, unit: ppm
* @note Five levels: Excellent(400 - 600), Good(600 - 800), Moderate(800 - 1000),
* @n Poor(1000 - 1500), Unhealthy(> 1500)
*/
uint16_t getECO2(void);
Air Quality Index
AQI Reference
| Level | Description | Suggestion | Recommended Stay Time |
|---|---|---|---|
| 5 | Extremely bad | In unavoidable circumstances, please strengthen ventilation | Not recommended to stay |
| 4 | Bad | Strengthen ventilation, find sources of pollution | Less than one month |
| 3 | Generally | Strengthen ventilation, close to the water source | Less than 12 months |
| 2 | Good | Maintain adequate ventilation | Suitable for long-term living |
| 1 | Excellent | No suggestion | Suitable for long-term living |
eCO2/CO2 Concentration Reference
| eCO2/CO2 | Level | Suggestion |
|---|---|---|
| 21500 | Terrible | Indoor air pollution is serious and requires ventilation |
| 1000-1500 | Bad | Indoor air is polluted, ventilation is recommended |
| 800-1000 | Generally | Can be ventilated |
| 600-800 | Good | Keep it normal |
| 400-600 | Eexcellent | No suggestion |
TVOC Concentration Reference
| TOVC(ppb) | Effects on Human Health |
|---|---|
| >6000 | Headaches and nerve problem |
| 750-6000 | Restless and headache |
| 50-750 | Restless and uncomfortable |
| <50 | No effect |